The
amplifier-conditioner COND A420 provides a
normalised signal in current and voltage from every
transducer based on the strain-gauge technology.
Input Signal
: from 0.5 to 2 mV/V
:
Excitation of 1 to 4 load cells 350
ohms
: Excitation 10 VDC (120 mA max. )
: Adjusting range of gain from 500 to 2.000
: Adjusting range of zero 0 to 75 %.
Output signal
: 0..10 VDC : (minimum
load 1 kilo
ohms
)
: 0..20 mA : ( maximum load 800
ohms
)
: 4..20 mA : (maximum load 800
ohms
)
Accuracy
: Non-linearity
: ± 0.01% of
full scale
: Zero drift :
±
200 ppm /°C of full scale
: Thermic drift on span :
±
60 ppm /°C of signal
Specifications
: Frequency response :
0..10Hz (-3dB, 12dB/octave )
: Operating temperature : - 10°C.. + 60°C
Adjustment
: Zero point and full scale by
potentiometer on the front panel.
Power supply
: 110, 220 VAC (+10/-15%) 50/60 Hz
Consumption
: 3 VA
Housing
: NORYL, weight 0.25 kg, socket ABS
: Din rail mounting (EN50022)
|